|
Healthcare Professionals -
HPMS, Inc The Therapy Connection is
your Best Resource for Chiropractic/Physical Therapy Equipment & Supplies!________________________________________________________
Resistive
Exercise | Rehab Equipment | Supply | Cervical Lumbar Support Pillows | Reusable Hot Cold Therapy | Electrotherapy
| TENS | Interferential | Electronic Muscle Stimulator | Treatment Massage Tables | Medical | Chiropractic | Physical Therapy
|
Links to Life-Tech® Iontophoresis Treatments | Meditrodes:
Scroll down for NAImco Medical's ionto
+plus Iontophoresis Electrodes
Life-Tech® Iontophoresis Treatment Meditrodes Sizes
Life-tech® Iontophoresis Meditrodes | Electrodes Configurations
Life-Tech® Iontophoresis Treatment Meditrode CliniPak - save up to 60%!
Iontophoresis Meditrode Sale Flyer - Save 60% on Treatments
Life-tech® Iontophoresis Treatment - Meditrode | Electrode Application Instructions 6550 | 6560 | 6570 Series
Life-Tech® Iontophoresis Treatment Drug Delivery Electrode Insert Sheet
Life-tech® Iontophoresis Meditrode | Electrode Sample Request - Mention www.HPMS.com
Life-tech® Iontophoresis Meditrode Data Sheets
Iontophoresis Patient Consent Forms - Every patient should sign - download for clinic | patient protection.
Iontophor® II Model 6111PM/DX
|
SPECIFICATIONS
Size: 3.75" x 1.75" x 7" (9.5cm x 4.5cm c 17.8cm) Weight: 1.2 lbs.
(545 gm) Power Source: Four, AA size Alkaline batteries Display: Liquid Crystal Display (LCD), utilizes
supertwist technology for high contrast and a wide viewing angle. Current Range: 0-4.0mA in 0.02mA increments. Accuracy:
3% of setting, worst case. Treatment Dose Range: 0-150 mA-minutes in 1 mA-minute increments. Open Circuit
Driving Voltage: greater than 100 VDC. Drug Polarity: Drug delivery electrode can assume "+" or "-" for either
phase. Cable Length: 3 feet (76cm), ultra flexible, touch-proof leads.
|
FEATURES
Fully Programmable Iontophor-PM/DX allows you to enter and store commonly-used
protocols for later recall.
Select Single or Dual Phase Treatments With Iontophor-PM/DX, you can perform both
single and dual phase treatments. The unit automatically reverses drug polarity and transfers the current to Phase II when
the dual phasemode is selected.
Dual Treatment Capability Iontophor-PM/DX's dual site treatment function enables
you to treat two sites simultaneously, saving time and increasing cost effectiveness.
Accurately Maintains Current for Precise Dose Delivery Iontophor-PM/DX maintains
current against impedances as high as 40,000 ohms, permitting treatment of all areas, including scar tissue.
Identifies and Displays Open Circuit When inadequate patient contact occurs, Iontophor-PM/DX
indicates "OPEN". When patient contact is re-established, the current automatically returns to the preset level, and delivery
continues until the required dose is achieved. |
|
|
Iontophor PM/DX Data Sheet
Life-Tech®, Iontophor
PM Deluxe (4.0 max milliampere output). Includes Model (6513TP) IOP dual applicator cable, batteries, (61196TP)
dual treatment lead wire, (H1556) red meditrode® lead wire, (H1557) black meditrode lead wire®, (SA1192) test lead wire and
operator's manual. 1 year manufacturer warranty.
|
Retail $
523.95
HPMS $
$493.95
|
|
| |
|
|
|
Microphor® Model 6121
|
SPECIFICATIONS
Size: 2.4" x 0.8" x 4.2" (6.1cm x 2cm c 10.7cm) Weight: 5 oz (142 gm)
including battery Power Source: 9V Alkaline battery Battery Indicator: Illuminates when time to replace
battery. Current Range: Ten (10) fixed settings from 0.5 to 4.0mA. Time Range: Ten (10) fixed settings
from 3 to 20 minutes. Treatment Dose Range: One hundred (100) fixed dose values from 1.5 to 80 mA-minutes. Open
Circuit Driving Voltage: approximately 100 VDC. Impedance Range: 0-15 Kohms with application current of 4.0mA;
0-20 Kohms with application current of 3.5mA or less. Drug Polarity: Drug delivery electrode can assume "+" or "-"
for either phase.
|
FEATURES
Minimal Setup Required You only set current, time, and polarity.
Dual Treatment Capability The dual site treatment function enables you to treat
two sites simultaneously, saving time and money.
Identifies and Displays Open Circuit When inadequate patient contact occurs, Microphor®
indicates "OPEN". When patient contact is re-established, the current automatically returns to the preset level, and delivery
continues until the required dose is achieved.
Drives Positive and Negative Ions Microphor® requires only a touch
of the switch to move from positive to negative ions, eliminating the need to switch leads.
Automatically Prevent Application of Current Transients Microphor®
automatically ramps up and ramps down for both "ON" and "OFF" to prevent application of current transients. |
| |
Microphor Data Sheet
|
|
|
|
|
Life-Tech®, MicroPhor®
(4.0 max milliampere output). Includes (1) nine volt battery, (61196) dual treatment lead wire, (H1196) red
meditrode® lead wire, (H1197) black meditrode® lead wire, (C400) IOP applicator cable, dose chart and operator's manual. One
Year manufacturer warranty.
|
Retail $
$420.00
HPMS $
$410.00
|
|
Iontophoresis Treatments
Life-Tech® Meditrode Systems
6580 CliniPak Iontophoresis
Series
 Meditrode©
CliniPak Model 6580
|
 |
The
Meditrode CliniPak is designed to reduce the overall time of administering an iontophoretic treatment regiment. Five sets
of six patient treatments are contained in individual
resealable packs, labeled with the patient's information
and filed in the multi-patient file box for easy
access.Washing sponges and wrapping or taping bulky carbon
reusable electrodes is eliminated. The large self-adhering, reusable
dispersive provides maximum comfort and is easily returned to its storage liner and pack for the next
treatment.
You will enjoy the convenience of having everything you need in one package with up to a 60%
cost savings!
Advantages
| 1 |
Provides exact number of Meditrodes for treatment regiment. |
| 2 |
Large, self-adhering, reusable
dispersive for maximum comfort. |
| 3 |
File box design provides easy
access to five individual patient paks. |
| 4 |
One box replaces 3 standard
boxes. |
| 5 |
Up to 60% cost reduction! |
| 6 |
Available in 5 shapes and 7
sizes. | | |
Each CliniPak contains (6) active Meditrodes,
(1) self adhering, reusable hydrogel return electrode, (6) alcohol pads, (1) bottle (100 ml) premixed buffer solution
and (1) application instruction card. Each box contains 5 paks.
|
|
|
Part #
|
Description
|
Price
|
|
Add to
Cart
|
|
|
Life-Tech®, Large
Square Meditrode
Clinipak Individual
Patient Kit - Each
|
List Price
$168.30
HPMS Price
$158.30
|
|
|
|
|
Life-Tech®, Medium
Square Meditrode
Clinipak Individual
Patient Kit - Each
|
List Price
$118.35
HPMS Price
$108.35
|
|
|
|
#6580R
|
Life-Tech®, Large
Round Meditrode
Clinipak Individual
Patient Kit - Each
|
List Price
$130.00
HPMS Price
$120.00
|
|
|
|
|
Life-Tech®, Small
Rectangular Meditrode
Clinipak Individual
Patient Kit - Each
|
List Price
$107.00
HPMS Price
$97.00
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
Iontophoresis Treatment
Life-Tech® Iontophoresis Meditrodes
6551 Series - Contour Style
Includes: Delivery Only, Box of 20
|
|
Size:
4.25"x2.75" Delivery Area: 3.5 sq. inches Fluid Capacity: 6-8cc
HPMS $114.00
|
|
|
|
Size:
5.25"x3.5" Delivery Area: 5.23 sq. inches Fluid Capacity: 8-10cc
HPMS $124.00
|
|
Iontophoresis Treatment
Life-Tech® Iontophoresis Meditrodes -
6560 Series Kits
Includes: Delivery, Return & Solution, Box of 10
sets
|
|
Size: 1.5"x3.5" Delivery Area: 1 sq. inch Fluid Capacity:
1-2cc
HPMS $54.00
|
|
|
|
Size: 2.25"x2.25" Delivery Area:
2 sq. inches Fluid Capacity: 2-3cc
HPMS $57.00
|
|
|
|
Size: 4"x4" Delivery Area: 6 sq. inches Fluid
Capacity: 7-9cc
HPMS $60.90
|
|
Iontophoresis Treatment
Life-Tech® Iontophoresis 6570
Series -
Includes: Delivery Only - Individually
Packed, Box of 20
|
|
Size: 1.5"x3.5" Delivery Area: 1 sq. inch Fluid Capacity:
1-2cc
HPMS $56.90
|
|
|
|
Size: 2.25"x2.25" Delivery Area:
2 sq. inches Fluid Capacity: 2-3cc
HPMS $59.55
|
|
|
|
Size: 4"x4" Delivery Area: 6 sq. inches Fluid
Capacity: 7-9cc
HPMS $63.85
On-Line Special
$49.95*
*while supplies last
|
|
Image Coming Soon
Round
6570R
|
Size: 3.5" dia. Delivery Area: 4.9
sq. inches Fluid Capacity: 6-8cc
HPMS $61.20
|
|
Life-Tech® Iontophoresis Treatment
Return Electrodes & Buffer Solution
Image Coming Soon
Gel-Trode
Small Return
6585SR
|
Size: 2" x 2"
Self-Adhering, Buffered, Dispersive Electrode
Box of 20
HPMS $56.10
NOTE: Use with Small Meditrode Systems.
|
|
Image Coming Soon
Gel-Trode
Large Return
6585LR
|
Size: 4" x 4"
Self-Adhering, Buffered, Dispersive Electrode Box of 20
HPMS $91.00
NOTE: Use with Medium, Large and Round Meditrode Systems.
|
|
|
|
Pre-mixed Meditrode Buffer Solution
Box of 6, 100ml Bottle
HPMS $27.00
|
|
Life-Tech® Iontophoresis Treatment
Iontophoretic Acessories
Cables & Lead Wires
|
|
6513TP
Life-Tech® IOP applicator cable for the Iontophor®
PM, Touch-proof. Connects the Iontophor PM to the H1556, H1557 for single site treatment and the 61196TP and H1557 for dual
site treatment. Price $57.25
|
|
IOP Applicator Cable
|
C400
Life-Tech® IOP applicator Cable for the MicroPhor,
model 6121. Touch-proof. Connects the MicroPhor to the H1556 and H1557. Price $70.75
|
|
|
H1560
Life-Tech® Red Meditrode delivery lead wire (single treatment)
touch proof, 60 inches long $16.00 each
|

Black Delivery Wire
|
H1561
Life-Tech® Black Meditrode return lead wire (single treatment)
touch proof, 60 inches long $16.00 each
|

Red Delivery Wire
|
H1556
Life-Tech® Red Meditrode delivery lead wire (single treatment)
touch proof, 24 inches long $16.00 each
|
|
|
H1557
Life-Tech® Black Meditrode return lead wire (single treatment)
touch proof, 24 inches long $16.00 each
|

Dual Treatment Lead
|
61196TP
Life-Tech® Dual treatment lead wire. For use with the 6513TP
and H1557 for dual site treatment Dual Treatment Lead Wire has resistor to assure equal medication delivery to both
sites. $36.25 each
|
Snap-to-Electrode Connector
|
6590S
Life-Tech® snap-to-electrode connector. Package of 1 pair.
Adapts the Meditrodes® to the Iomed Phoresor (Touch-proof connectors) $27.75 each
|
Iontoplus Iontophresis Electrode Systems -
Naimco Medical
Each size electrodes contains 12 kits/box,
Each kit contains 1 Active Electrode, 1 Buffered Return Electrode, 2 Alcohol
Prep Pads
|
Small
2.75"x 2.75"
Square,
fill 1.5cc, 3.0mA -
#201-395
|
Medium
3.25"x 3.25"
Square,
fill 2.5cc, 4.0 mA -
#201-396
|
Large
3.5"x 3.5"
Square,
fill 4.0cc, 4.0 mA -
#201-397
|
Butterfly
3.375"x 3.75",
fill 2.0cc, 3.0mA -
#201-398
|
Id³
Dual Channel
Iontophoresis
Drug Delivery
Device
#202-351
|
|
|
|
|
|
|
|
|
 |
|
 |
 |
|
 |
|
|
|
Dual Channel
Detects skin impedance changes and compensates
Single or dual phase polarity(no lead wire change)
Ramp-up adjustable to patient tolerance
Memory save last parameters
Low power consumption
Compact 4.5" x 2.7", 3.6oz. |
| |
 |
Greater adhesive area eliminates pad movement
Unique Silver-Silver Chloride conductor (superior to carbon) Higher Conduction=More Drug Delivery
No buffering or gelling agents that can impede drug transfer | |
 |
 |
 |
|
Synthetic Gel offers better adhesion than Karaya Provides maximum
current dispersion Increases patient comfort level
Synthetic Buffering provides consistent pH balancing Helps prevent
the effects of hydrolysis
No water needed to activate the adhesive No chance of contamination
by water |
| |
|
|
 |
|
BUTTERFLY (2.0cc/3.0mA 3.375"x3.75" P/N 201-398 | |
|
 |
 |
|
SMALL (1.5cc/3.0mA 2.75"x2.75" P/N 201-395 | |
|
 |
|
MEDIUM (2.5cc/4.0mA 3.25"x3.25" P/N 201-396 | |
|
|
 |
Greater adhesive area eliminates pad movement
Unique Silver-Silver Chloride conductor (superior to carbon) Higher Conduction=More Drug Delivery
Buffering agents for additional pH stabilization | |
 |
 |
 |
|
Synthetic Gel offers better adhesion than Karaya. Provides
maximum current dispersion Increases patient comfort level
Synthetic Buffering provides consistent pH balancing Helps prevent
the effects of hydrolysis
No water needed to activate the adhesive No chance of contamination
by water |
| |
|
|
 |
|
BUTTERFLY (2.0cc/3.0mA 3.375"x3.75" P/N 201-452 | |
|
 |
|
SMALL (1.5cc/3.0mA 2.75"x2.75" P/N 201-455 | |
|
 |
 |
|
MEDIUM (2.5cc/4.0mA 3.25"x3.25" P/N 201-449 | |
|
|
 |
|
 |
|
|
|
 |
 |
 |
 |
 |
|
Iontophoresis—an overview |
|
|
|
Definition
Iontophoresis is the process by which drugs, usually dexamethasone
and lidocaine, are introduced into a joint or small body part via electrical current. It is non-invasive, painless and it
eliminates potential side effects and adverse reactions which can occur with medications delivered orally or by injection.
Clinical trivia: ionto provides more local concentrations
than medications taken by mouth, but less than injected medications.
Basic process
·Like electrical
charges repel each other; current is used to repel like electrically charged ions (medication) to penetrate skin and underlying
soft tissues.
· Dc generator provides
electrically charged field for medication movement into tissues.
· Dexamethasone carries
a negative charge when dissolved in a solution so it will always be applied to the cathode (negative/delivery) electrode for
delivery.
· Medication is delivered
to local area via cathode or active (delivery) electrode and current returns to unit via anode or dispersive (return) electrode.
3 basic components
1. Dc generator: provides direct (galvanic) current
- Typically treatment time: 4ma over 10 minutes or 40ma
- Cathode and anode are determined by which lead is connected with
each electrode
2. Active (delivery electrode)
- 3 layers
- Foam reservoir pad: holds ionic solution to be delivered
- Polyester fild coated w/ silver/silver chloride: conduct the current
evenly across the reservoir
- Soft, flexible foam coated with a medical grade adhesive
3. Dispersive (return electrode)
- 3 layers
- Self-adhering buffered conductive polymer: provides stabile environment
to prevent skin irritation/burns
- Conductive (carbon) film: evenly distributes current across
the electrode
- White non-conductive vinyl-like material
|
|
 |
 |
|
Facts about iontophoresis
Adhesion is the most important factor; better contact equals
better conduction/maximum drug delivery with least chance for burns/hot spots.
· All manufacturers
use buffering gels on the return electrodes.
· Some Manufacturers
use buffering agents on delivery electrodes when carbon film is used in place of silver/silver chloride (carbon
film does not provide a stabile conductive environment).
· In orthopedic rehab,
99.9% therapy is to deliver dexamethasone (anti-inflammatory drug).
· Current used: direct
(galvanic) current only; provides uni-directional electrostatically charged field from active to return electrode.
· Since dexamethasone is typically used in orthopedic rehab we will assume all statements regarding
ionto relate to this medication.
Important note regarding
electrophysiology at both electrode sites
Even in the absence of medication, an alkaline reaction occurs at
the cathode due to the formation of sodium hydroxide while an acidic reaction occurs at the anode due to formation of hydrochloric
acid.
Important for pad properties to have a stabilizing mechanism in
place to prevent this shift (acidic and basic ph shifts can cause burns). Silver/silver chloride provides this stabilization;
some manufacturers use carbon film for conduction which requres the addition of a buffering pad, gel, powder to provide stabilization.
(please see competitive product sheet for pad properties). |
 |
|
 |
|
|
|
|
|
 |
 |
|
Download a product brochure. 7.5Mb | |
Helpful Links:
Life-Tech, Inc. Website | Iontophoresis
Life-Tech, Inc. Meditrode Request Form
|